| Sign In | Join Free | My insurersguide.com |
|
Brand Name : BOTO
Model Number : BT-150
Certification : CE ISO
Place of Origin : China
MOQ : 1set
Payment Terms : L/C, T/T
Supply Ability : 50 Set/Sets per Month
Delivery Time : 5-25 days
Packaging Details : wooden case
Power : Electronic
Temperature evenness : ≤±2℃
Inner dimension : 50*60*75cm
Humidity Deviation : ±2%R.H
Humidity range : 20%~98%RH or 10%~98%RH
Color : Light and dark grey or customize
Temperature and Humidity Vibration Comprehensive Test Chamber
Standard features
| Temperature and humidity vibration comprehensive test Chamber | |||||
| Model | BT-150 | BT-250 | BT-400 | BT-600 | BT-010 |
| Workroom size (cm) | 50x50x60 | 60x60x70 | 70x70x80 | 80x80x90 | 100x100x100 |
| Table size | 30x30 | 40x40 | 50x50 | 60x60 | 80x80 |
| Temperature range | A: -20℃~150℃ B: -40℃~150℃ C: -60℃~150℃ D: -70℃~150℃ T: -120℃~130℃ | ||||
| vibration circle size | Φ200mm~Φ400mm | ||||
| Sinusoidal excitation force | 500Kg~3000Kg | ||||
| Continuous displacement | 51mm | ||||
| Frequency Range | 5-2000HZ | ||||
| speed | 2m/s | ||||
| Volatility/uniformity | ±0.3℃ /±2℃ | ||||
| Humidity range | 20%~98%RH(10%~98%RH) | ||||
| Humidity deviation | -2%~-3% | ||||
| Heating speed | 1.0℃ ~3.0℃ /min | ||||
| Cooling speed | 0.7℃ ~1.2℃ /min | ||||
| Heating time | RT℃ ~150℃ ≤30min | ||||
| Cooling time | RT℃~-40℃≤60min | ||||
| Noise | ≤72 dB(A) | ||||
| Sample tray load | ≤20kg | ||||
| Operating power | ~3.25KW | ~3.55KW | ~3.95KW | ~5.5KW | ~6.25KW |
| Material | Inner chamber:# SUS 304 stainless steel | Exterial material:cold rolled sheet powder-coated/#SUS304 stailess steel | |||
| Wind cycling type | Forced drive of centrifugal impeller | ||||
| Cooling type | Single-stage refrigeration/double cascade | ||||
| Compressor | "Tecumseh" from France / "Copeland" from USA | ||||
| Refrigerants | R4O4A Dupont Environmental refrigerants/R23 | ||||
| Cooling method | Wind cooling/ water cooling | ||||
| Heater | 316LSeamless stainless steel fin heater / nickel-chromium alloy heating wire heater | ||||
| Humidifier | External stainless steel boiler humidifier | ||||
| Water supply method | Automatic replenishment method | ||||
| Control instrument | TEMI880 or OYO-8256P or HLS950or E300 | ||||
| Related standards | Technical conditions of GB10586-89 damp heat test chamber | ||||
| GB/T2423.2—93 (equivalent to IEC68-2-3) | |||||
| Technical conditions of GB10592-89 high and low temperature test chamber ℃ | |||||
| GB2423.1—2001 Part 2: Test Method Test A: Low Temperature | |||||
| GB2423.2—2001 Part 2: Test Method Test B: High Temperature | |||||
| Technical conditions of GB10589-89 low temperature test chamber | |||||
| GB11158-89 Technical conditions of high temperature test chamber | |||||
| GJB150.9A-2009 Military Equipment Laboratory Environmental Test. Method Part 9: Damp heat test | |||||
| GJB150.4A-2009 Military Equipment Laboratory Environmental Test. Method Part 4: Low Temperature Test | |||||
| GJB150.3A-2009 Military Equipment Laboratory Environmental Test.Method Part 3: High Temperature Test | |||||
| Stand Accessories | 1 Observation window (multi-layer hollow heat conduction anti-fog type) | ||||
| 1 50mm test hole | |||||
| 1 U-shaped energy-saving lamps | |||||
| 1 Sample rack | |||||
| 1 Wet and dry ball gauze | |||||
| 3 Resettable fuse | |||||
| 1 The power supply cable is 3 meters. | |||||
| Safety Device | Compressor overload protection | ||||
| Phase sequence/phase loss protection | |||||
| Humidifier anti-dry protection | |||||
| Mechanical over-temperature insulation | |||||
| Water tank shortage protection | |||||
| Temperature and humidity characteristic curve | ![]() | ||||
Company introduction



Production line and workshop


Other products:

Company certifications


Company partners

|
|
Temperature And Humidity Vibration Comprehensive Test Chamber Images |